另类视频网站|日韩激情不卡视频|国产爆乳精品免费观看一牛影视|久久人妻精品秘书丝袜激

  • Golden knight TDX - 3330 gs
< >
  • Golden knight TDX - 3330 gs

Golden knight TDX - 3330 gs

product power:24KW(千瓦)

product capacity:30KVA 【View products of the same capacity】

series:Power frequency TDX series 【View the same series of products】

voltage input and output:Three in and three out (380V:380V)

weight:243 kg

size(LWH):481*890*1175 MM 27U

Shape classification:

  • Product Overview
  • For details
  • Installation Notes
  • Product Image
  • After-sales service
  • Documentation
  • ● Advanced DSP digital control technology

    Adopt advanced digital DSP control technology, make data processing more accurate and rapid, output performance will be more excellent, improve the reliability of the machine.

    ● Large LCD+LED display screen

    Fully considered humanized design, LCD+LED perfect combination, Chinese and English display, display content is rich and easy to understand, easy to operate. LCD display panel is more equipped with switch protection device, to avoid collision or mispress and all kinds of problems, users in the process of using more safe and reliable.

    ● High guarantee double channel AC power input function

    The main AC input power supply and the bypass AC input power supply can be used as two sets of inputs from different power grids, so that the power supply of users can be more fully guaranteed.

    ● Frequency and phase sequence adaptive system

    The output frequency can be set to either 50Hz or 60Hz depending on the mains frequency. The output phase sequence can automatically track the phase lock according to the input phase sequence.

    ● Intelligent charging system

    The user can freely set the appropriate charging current (1~25A) on the LCD control panel according to the battery type, capacity and the use state of the battery. Scientific charging way, make the service life of the battery has been extended adequately.

    ● More excellent electrical performance

    The efficiency of the whole machine is as high as 93%~94%, and the ECO mode is provided to improve the efficiency to more than 97%, greatly reducing the power loss of UPS. The full bridge topology with output isolation transformer is adopted, which has stronger load capacity and impact resistance. The output load power factor reaches 0.8.

    ● Parallel function

    Support 3 UPS parallel redundancy (option).

    ● Excellent battery management features

    TDF series UPS can automatically detect abnormal phenomena such as battery failure, low power, battery loss, etc., which further improves the reliability and safety of UPS.


    TDX-3330GS The main input

    modelTDX-3330GS
    The rated voltage380V
    Input modeThree phase three phase + protection ground wire
    Voltage range-50% ~ +25% (-25% ~ -50% frequency reduction required for quality inspection)
    Rated operating frequency50Hz
    Input power factor>0.99
    Input harmonic current<6%

    TDX-3330GS Bypass the input

    The rated voltage380V
    Input modeThree phase four wire
    Voltage range380V-50%~+25%
    Frequency range40Hz~60Hz

    TDX-3330GS The output

    Rated power30KVA/27KW
    The rated voltage380V
    Output voltage range200/208/220/230/240VAC
    The output wiringThree phase four phase + protection ground wire
    Steady-state voltage accuracy±1%
    Dynamic voltage transient≤9%
    Dynamic transient recovery time≤60ms
    Output voltage waveform distortion degree≤2% (linear load); ≤8 (nonlinear load)
    The power factor0.9
    Frequency tracking range46Hz~54Hz
    Frequency accuracy (battery inverter)(50±0.1)Hz
    Three phase difference120±1°
    Frequency tracking rate1Hz/Sec
    Overload capacityWhen 105%±5%≤ load, alarm overload; When 105%±5% < load ≤125%±5%, turn to bypass output in 10 minutes; When 125%±5% < load ≤150%±5%, turn to bypass output for 1 minute; Load > 150%±5%,, turn to bypass output after 500ms
    Peak output current ratio≥3:1
    Switching time (normal mode)≤4ms

    TDX-3330GS system

    According toLCD
    EMS/EMI Conduction/radiationIEC 62040-02
    EMS/EMI The perturbation resistanceIEC 61000-4-2.4.5 Level IV,IEC 61000-4-3 Level III
    Safety requirementsGB4943-2001/IEC62040-1
    Noise (distance 1m)≤55dB
    Insulation resistance(Ω)>2M(500VDC)

    TDX-3330GS The environment

    Working temperature0℃~40℃
    At an altitude of< 1000m(load decreases by 1% for every 100m increase over 1000m)
    Storage temperature-15℃~45℃
    Working humidity20%~95%

    TDX-3330GS The other parameters

    The battery384VDC
    Cabinet size (depth x width x height mm)481*890*1175
    The weight of the(Kg)243



    10KVA AC 220V input: AC 220V output

    The input parameters
    The input voltage380V AC 
    Input wire diameter16mm2 
    Enter zero line diameter16mm2 
    Input ground line diameter16mm2 
    Enter the open100A -3P 
    Output parameters
    The output voltage3800V AC 
    Output wire diameter10mm2
    Output zero line diameter10mm2
    Output line diameter10mm2
    Output open63A -3P 
    Battery parameters
    The external battery is empty100A-2P 
    External battery wire diameter16mm2

    10KVA AC 380V input: AC 220V output

    The input parameters
    The input voltage380VAC 
    Input wire diameter16mm2 
    Enter zero line diameter16mm2 
    Input ground line diameter16mm2 
    Enter the open100A -3P
    Output parameters
    The output voltage380VAC 
    Output wire diameter10mm2
    Output zero line diameter10mm2
    Output line diameter10mm2
    Output open63A -3P
    Battery parameters
    The external battery is empty100A-2P 
    External battery wire diameter16mm2

    10KVA AC 380V input: AC 380V output

    The input parameters
    The input voltage380VAC 
    Input wire diameter16mm2 
    Enter zero line diameter16mm2 
    Input ground line diameter16mm2 
    Enter the open100A -3P 
    Output parameters
    The output voltage220V AC 
    Output wire diameter25mm2 
    Output zero line diameter25mm2 
    Output line diameter25mm2 
    Output open36A -1P 
    Battery parameters
    The external battery is empty100A-2P 
    External battery wire diameter16mm2


    500×500
     TDX-3330GS_1
    500×500
     TDX-3330GS_2
    500×500
    TDX-3330GS_3
    500×500
    TDX-3330GS_4

    Backup model: one year warranty built-in battery one year warranty


    Online model: 3-year warranty


    12V24AH capacity battery products: three-year warranty


    All over the country after sales service contact: contact us


    7*24 hour service tel: 400-830-8833


    related product recommendation