另类视频网站|日韩激情不卡视频|国产爆乳精品免费观看一牛影视|久久人妻精品秘书丝袜激

  • Golden Samurai VT 33010G
< >
  • Golden Samurai VT 33010G

Golden Samurai VT 33010G

product power:8KW(千瓦)

product capacity:10KVA 【View products of the same capacity】

series:High frequency VT series 【View the same series of products】

voltage input and output:Three inputs and three outputs (380V:380V)

weight:83.5 kg( 公斤)

size(LWH):710*260*717 MM(毫米)17U

Shape classification:

  • Product Overview
  • For details
  • Installation Notes
  • Product Image
  • After-sales service
  • Documentation
  • ●Advanced DSP digital control technology

    The Golden Samurai VT series adopts advanced DSP digital control technology, which not only improves product performance, but also greatly meets the needs of users for the practicability, efficiency, reliability and safety of power supply products. Even if the electrical environment is harsh, it can ensure the stable and continuous operation of the equipment.

    ●Ultra wide input voltage range

    The VT series provides users with an ultra-wide input voltage range, and can work stably in the mains power supply mode even in harsh grid environments, reducing the number of battery discharges, prolonging the battery life, and saving usage costs.

    ●Frequency Adaptive System

    Users can set to a fixed 50HZ or 60HZ system, or set to automatically recognize and adapt to 50HZ / 60HZ power system to meet the requirements of different power systems.

    ●The output power factor is 0.9

    Adapt to the characteristics of most current electrical equipment to achieve stronger load capacity.

    ●Active input power factor correction (PFC)

    The VT series adopts digitally controlled active power factor correction technology (PFC) to make the input power factor close to 1, so as to avoid pollution of the grid environment and achieve the purpose of energy saving and system cost reduction.

    ●Wide input frequency range

    The wide input frequency range enables the UPS to adapt to different power supply equipment such as generators, effectively isolate the bad power generated by the power supply equipment, and provide pure, safe and stable power for the load.

    ●Green

    This product is a green and environmentally-friendly product, which complies with the National Electronic Information Product Pollution Control and Management Measures to ensure that the product will not cause harm to the environment and people under normal use.

    ●Powerful expandability function

    The intelligent slot provides a wealth of expandable functions, you can choose from USB card, AS400 card, CMC monitoring card, SNMP card, RS485 card, EMD environmental monitoring card.


    • VT-33010G detailed parameter table

      Rated Capacity10KVA/9KW
      modelVT-33010G

      VT-33010G input parameters

      Rectifier typeIGBT rectification
      Rated voltage380Vac
      Input voltage range210VAC~475VAC 3P4W+G
      Input frequency range40Hz~70Hz(Adjustable)
      Input power factor0.99

      VT-33010G output parameters

      Rated output power10KVA / 9000 W
      Rated output voltage380Vac
      The output voltage220VAC(1±1%)1P2W+G
      Output frequencyMains power: 46-54Hz synchronous mains; 50Hz (mains 40-46Hz or 54-60Hz); battery: 50Hz
      Output power factor0.9
      Way of workingOnline
      Output waveformSine wave
      Switching time0ms
      Overload capacity105% < load ≤ 125% Bypass alarm in 1 minute; 125% < load ≤ 150% Bypass alarm in 30 seconds; Bypass alarm in 300ms with load > 150%
      EfficiencyMains power: ≥93%; battery ≥90%
      EOC/EPOOptional

      VT-33010G battery and running time

      battery modelValve-regulated maintenance-free lead-acid battery
      Standard machine backup time30 minutes to 8 hours optional
      Battery pack model-
      Typical battery charging time10 hours
      battery voltage192VDC

      VT-33010G system parameters and standards

      Installation methodTower
      Overall efficiencyUp to 90%
      Electromagnetic CompatibilityICE/EN/AS 62040-1; CISPR 22 Class A
      Surge protectionICE/EN 62040-2, meet ICE/EN 61000-4-5
      Protection typeIP20
      Short circuit protectionHave

      VT-33010G communication and management

      Interface portRS232, optional Wedpower card, AS400 card
      control panelLED status indication
      Audible alarmAlarm once every 4 seconds when mains power fails: special low battery alarm once every second

      VT-33010G physical indicators

      W710.00 mm
      D260.00 mm
      H717.00 mm
      weight83.5(45) KG
      colorblack

      VT-33010G environment

      working environment0 - 40 °C
      Relative humidity20%-90%
      Operating height0-1500 meters
      storage temperature-5 - 45 °C
      Storage relative humidity0 - 95%
      Storage height0-15000 meters
      Audible noise at 1 m from the surface of the device≤60.00 dB

      VT-33010G warranty

      Standard warrantyRepair or replace within 3 years




    10KVA AC 220V input: AC 220V output

    Input parameters
    Input voltage220V AC (Single phase double wire)
    Enter the live wire diameter10mm2 (Square millimeter)
    Input zero wire diameter10mm2 (Square millimeter)
    Input ground wire diameter10mm2 (Square millimeter)
    Input air switch80A -1P (AC open)
    Output parameters
    The output voltage220V AC (Single phase double wire)
    Output wire diameter16mm2(Square millimeter)
    Output neutral wire diameter16mm2(Square millimeter)
    Output ground wire diameter16mm2(Square millimeter)
    Output MCB80A -1P (AC open)
    Battery parameters
    External battery MCB100A-2P (DC MCB)
    External battery wire diameter10mm2(Square millimeter)

    10KVA AC 380V input: AC 220V output

    Input parameters
    Input voltage380V AC (Three-phase four-wire)
    Enter the live wire diameter10mm2 (Square millimeter)
    Input zero wire diameter10mm2 (Square millimeter)
    Input ground wire diameter10mm2 (Square millimeter)
    Input air switch80A -3P (AC open)
    Output parameters
    The output voltage220V AC (Single phase double wire)
    Output wire diameter16mm2(Square millimeter)
    Output neutral wire diameter16mm2(Square millimeter)
    Output ground wire diameter16mm2(Square millimeter)
    Output MCB80A -1P (AC open)
    Battery parameters
    External battery MCB100A-2P (DC MCB)
    External battery wire diameter10mm2(Square millimeter)

    10KVA AC 380V input: AC 380V output

    Input parameters
    Input voltage380V AC (Three-phase four-wire)
    Enter hot wire diameter10mm2 (Square millimeter)
    Enter zero wire diameter10mm2 (Square millimeter)
    Enter ground wire diameter10mm2 (Square millimeter)
    Enter empty on80A -3P (AC open)
    Output parameters
    Output voltage380V AC (Three-phase four-wire)
    Output wire diameter10mm2 (Square millimeter)
    Output zero wire diameter10mm2 (Square millimeter)
    Output ground wire diameter10mm2 (Square millimeter)
    Output MCB80A -3P (AC open)
    Battery parameters
    External battery MCB100A-2P (DC MCB)
    External battery wire diameter10mm2(Square millimeter)



    500×500

    500×500

    500×500

    Backup model: One year warranty, one year warranty for built-in battery


    Online models: three-year warranty


    12V24AH capacity battery products: three-year warranty


    After-sales service contact information throughout the country: Contact us


    7*24 hours service telephone: 400-830-8833


    related product recommendation